1. Temperature control: boot press control button digital screen will display 180 degrees, which is the default automatic control of the temperature is 180 degrees, after Pro Plus or minus is to increase or decrease the temperature range, the electromagnetic oven is 270,240,220,200,180,160,140,120,100, 80, a total of 10 stalls stalls
Temperature control is generally used for frying
Firepower: boot display 2000W press the fire button digital screen will automatically default, namely power 2000W, after Pro Plus or minus is to increase or decrease, electromagnetic oven power range is 300,600,900,1200,1600,2000,2400,2800,3200,3500, a total of 10 stalls stalls
Thunderbolt key: induction cooker is a default boot 2000W, click on the arrow keys will be 3500
2. Insulation: press the button after the start of the heat preservation digital screen is displayed 80 degrees of heat preservation, but this function is not how much it is the temperature
3. Timing: in the working state of the fire, click on the timing function, the timing indicator light, the digital display 0:30 flashing, that is, 30 minutes after the automatic shutdown
The default automatic countdown shutdown function, by plus or minus is set, automatic shutdown time, plus or minus can each is plus or minus 1 minutes long hold can be set for 10 minutes, each function can be set to 3 hours long
Four digital tube in the first two hours, the last two minutes
Set the state in time if there is no operation within 5 seconds is automatically set the status quo, that is, the default status of the current set
4. Reservation: reservation indicator boot boot, the boot default automatic appointment function, plus or minus can increase or decrease is, every time, click on the plus increased 10 minutes, each click will reduce minus 10 minutes, if long hold time can increase or reduce the 1 boot time reservation the longest hours can be set for 24 hours
Four digital tube in the first two hours, the last two minutes
Note: due to the appointment of automatic boot, the film will automatically default 30 minutes to start the work, the machine will automatically shut down after 30 minutes