0 Piece,Product Price: US $ 0
Quantity(Piece/Pieces) | 1 ~ 1000 | >1000 |
Est. Time(days) | 7 | To be negotiated |
If you finish the payment today, your order will ship out within the delivery date.
Customized logo or packaging is available on led emergency module
Product Description:
Model |
FAT-LED-F1A |
Battery |
3.7V 2400mAh |
Input Voltage |
AC85-265V 50/60Hz |
Working Temperature |
0~55ºC |
Input power |
3W to 40W (50W max.) |
AC fuse |
1A 250V |
Output power |
4W |
DC fuse |
5A 250V |
Type of lamp |
LED luminaire with external led driver |
Switching time to Emergency |
<2S |
Charging time |
24Hrs |
IP Rating |
IP30 |
Backup duration |
>2Hrs |
Dimension |
133x55x21 mm |
Product images
FAT-LED-F1A:
Aluminum alloy external housing: high-performance heat dissipation for emergency devices
FAT-LED-F1A-2 (3-40W led emergency power supply): with external test button indicators
FAT-LED-F1A-CB: PASS CB FROM TUV.
FAT-LED-F1C: for 3-30W LED with external driver.
FAT-LED-F1C-2: with external test button and indicator; for 3-30W LED with external driver.
Battery and light source
Note: The positive and negative of battery should not be connected reverse, and we should avoid directly short-circuit the battery. Explosion will be caused if using unmatched battery. Please abide by local rules when discarding old battery.
Warning: As the inner PCB includes 220V/50HZ high voltage, so it must be unloaded/opened ONLY by professional technician.
Test button
Indicator Light
Problems |
Analysis |
Solution |
Green Light not working
|
Something wrong with the led driver |
Checking the led driver |
Green light is broken or the circuit is disconnected |
Checking circuit or changing green light |
|
Red light is off
|
Not being charged |
Checking the charging circuit or battery |
Red light is broken or the circuit is disconnected |
Checking circuit or changing red light |
|
Battery is full charged |
Disconnecting the main power supply, make the led lights work in emergency status for 30 minutes, make the led light return to work in main power status again |
|
Blue light is off
|
The battery is open circuit |
Checking the battery |
Light source is open circuit or short circuit |
Ensuring light source is connected correctly |
|
PCB is broken |
Checking the Maintaining the circuit board |
Dimension
Our Services
More LED EMERGENCY DRIVER FOR LED TUBES or Emergency backup lights:
Certification
With Certificate of design patent and utility model patent. CE RoHS CB approved.
Company Information