0 Piece,Product Price: US $ 0
Quantity(Piece/Pieces) | 1 ~ 1000 | >1000 |
Est. Time(days) | 7 | To be negotiated |
If you finish the payment today, your order will ship out within the delivery date.
1400W MPPT Wind Solar Hybrid Booster Charge Controller 12/24V With PWM dump loadCompatible with lithium/lead-acid battery
Please attention: Only Blue version has extra cable, and only Blue version support lithium battery, green don't support lithium battery.
Product Introduction
This kind of wind solar hybrid streetlight controller is special design for small off-grid wind solar hybrid generation system. Appearance is elegant, operations are easy. It also makes the course of which wind generator and solar panels charge to batteries safely and efficiently.
Functions and Feature
Ø Wind generator MPPT boost charging function.
Ø PWM dump load of wind, external dump-load resistance, intelligent disconnection of Solar charging.
Ø Dual power supply function: Battery + solar power supply.
Ø LCD displays parameters such as voltage and current of wind, solar and load .
Ø Two DC output, with 4 output modes.
Ø High performance and stable chip control.
Ø The inner circuit board of the controller is sprayed to prevent dust, moisture and static electricity.
Ø Protection:
Protection | Explain |
Reversed charging Protection of solar | Such as at night, the voltage of the battery may be higher than solar panel. The controller protect the battery from charging the solar panel. |
Reverse polarity Protection of battery | When the battery polarity is reversed, the controller does not work and there is no display. The fuse protects the internal circuit. If the battery does not work properly after it is connected correctly, just need to replace the fuse . |
Battery open circuit Protection | After long-term use, the battery may be Open-Circuit or poor connect. The controller can protect itself from damage. Check the connection regularly |
Over voltage, Over current or Over load Protection | When it’s strong wind or over voltage, the controller will automatically start braking function to protect the wind generator and battery. The controller will automatically cuts off the circuit when the output is over voltage. |
Lightning Protection | Lightning protection refers to the last level of protection necessary for equipment. For lightning-prone areas, special lightning protection devices and other components of the multilevel lightning protection system are needed. It need additional payment If the user need this function. |
Parameter Table
1. System Parameter | ||||||
Model | 400W20 | 500W30 | 900W50 | 1100W60 | 1400W80 | |
System Rated Voltage | 12V(9V-16VDC) | 24V(18V-32VDC) | ||||
Solar Module | Voc | 27.6V | 55.2V | |||
Vmp | >Vbat+1V | >Vbat+1V | ||||
Imp | 11.1A | 11.1A | 13.3A | 16.7A | 20A | |
Workable Power | 0W~200W | 0W~200W | 0W~400W | 0W~500W | 0W~600W | |
Wind Turbine | Rated Voltage | 12VAC(20.8VDC) | 24VAC(41.6VDC) | |||
Rated Current | 19.2A | 14.4A | 12A | 14.4A | 19.2A | |
Workable Power | 0W~400W | 0W~300W | 0W~500W | 0W~600W | 0W~800W | |
DC Load | Out Power | 0W~120W | 0W~250W | |||
Rated Voltage | 12VDC | 24VDC | ||||
Current Max | 20A(10A*2) | 20A(10A*2) | ||||
Conversion Efficiency | ﹥98% | |||||
Operation Mode | Default to streetlight mode | |||||
Environment | Temperature | 1) Working:-20℃ ~50℃; 2)Storage:-30℃ ~70℃ | ||||
Humidity (°C) | 10% ~ 90% No condensation | |||||
Protection Grade | IP30 | |||||
Weight | G.W | |||||
Size | Packing |
If your battery is 48V, please click on the following link, it's support 48V battery, and the max power is 2000W.
Appearance and size
Image of product
Installation and Electrical Connection
1.Resistance Wiring
$38.9~48.62
Min. Order:5
$38.9~48.62
Min. Order:5