Main technical parameters
Rated voltage: AC220V 50Hz/60Hz Power consumption: <3W Supply voltage: AC140V~320V Leakage range: 10~90mA Leakage response time: ≤0.1S Overvoltage range: AC220~300V Overvoltage response time: ≤0.1S Low voltage range: AC145~210V Low voltage response time: ≤0.1S Overcurrent range: 1~63A Overcurrent range response time: ≤0.1S Short-circuit current: ≥31ln Short-circuit response time: ≤0.1S Lightning protection: Test the switch with a combination wave of 1.2/50us (8/20us) between the L-N wires. No failure is found under the voltage of 2KV and no damage under 6KV. Error in real-time current, voltage and leakage current: ≤5% Max. failure records: 999 Temperature: -20°~55° Storage temperature: -45°~80° Humidity: ≤95%Rh Atmospheric pressure: 70kPa~106kPa
Purpose
It is intended for a circuit of AC 50Hz/60Hz with maximum rated current of 63A to protect it and the equipment involved against overvoltage, low voltage, current surge, leakage, lightning, etc. It is applicable to such electrical equipment as communication base stations, repeaters, video surveillance, Safety City, cable TV, digital TV, network switches, optical transceivers, meteorological telemetry stations, seismic detection stations in various conditions.
Features
Detection before closing: The automatic reclosing power protection switch monitors the circuit and will not close in occurrence of any overvoltage, leakage, overcurrent and other failures. Overvoltage protection: When the voltage between the live wire and naught wire of the input terminal is greater than the set value, it will trip the switch for protection. Low voltage protection: When the voltage between the live wire and naught wire of the input terminal is less than the set value, it will trip the switch for protection. Overcurrent protection: When the actual current is greater than or equal to 1.15 times the rated current for 3 seconds, it will trip the switch for protection. Leakage protection: When the leakage current exceeds the set value or an electric shock occurs, the automatic reclosing switch will be disconnected within 0.1 seconds to ensure personal safety. Neutral line disconnection protection: When the three-phase voltage is unbalanced to a certain level due to the loose or cut-off external Neutral line, the switch is tripped for protection. Automatic disconnection when power's off: The switch will be automatically disconnected when the circuit is powered off, and will be automatically reclosed after detecting a normal power supply restored. Intelligent leakage identification: Automatically detect before closing if the voltage is normal and the Neutral line is well-connected and never close in case of any failure. Automatic reclosing: Automatically reclose after a certain time interval if the above failure occurs. Automatically save tripping information: Automatically save such tripping information as tripping time, tripping type (cause), voltage, current and leakage current for failure analysis.