0 Piece,Product Price: US $ 0
Quantity(Piece/Pieces) | 1 ~ 1000 | >1000 |
Est. Time(days) | 7 | To be negotiated |
If you finish the payment today, your order will ship out within the delivery date.
PEAKMETER PM5910 Digital resistance meter RCD loop resistance tester Multimeter Trip-out Current/Time Test with USB Interface
Please Note:1.Not include battery and Color box!!!
2.Loop resistance During the measurement process, when the loop resistance is less than 10Ω, the instrument will display 0Ω, please purchase according to your actual use.
Packing List:
1 * RCD/LOOP Tester PM5910
1 * Test Lead
3 * Alligator Clip
1 * USB Wire
1 * CD-ROM
1 * Operational Manual
1 * Packaging Box
General Features:
1.Comply with IEC/EN 61010-1 1000V CAT II,600V CAT III Safety standards
2.Maximum common mode voltage:600V AC RMS
3.Display method:it is displayed on the LCD with maximum value at 6000
4.Measuring range selection:Auto/manual measuring range
5.Frequency detection:Auto
6.Overrange indication:”>”
7.Power consumption:100mW
8.Storage temperature:-20~70C
9.Working temperature:0~40C
10.Temperature factor:When the temperature is lower than 18C or above 28C the factor is per(°) x 0.05 x (appointed accuracy)
11.Electromagnetic compatibility:in a 3V/M RF (Radio Frequency) magnetic field,accuracy = appointed accuracy;otherwise,the accuracy is not appointed.
12.Storage elevation:12000m
13.Usage elevation:2000m CAT III 600V;3000 CAT II 600V
Specifications:
Item | Range | Accuracy | Resolution Power | |
Trip-out time | x1 IΔΝ300(slow 500ms) | ±3ms | 0.1ms | |
x5 IΔΝ40ms(slow 150ms) | ||||
Trip-out current | (0.2~1.1)IΔΝ | ±0.1 IΔΝ | 0.05 IΔΝ | |
Contactvoltage | 0~99.9V | ±(10%+0.2V) | 0.01,0.1V | |
AlternatingVoltage | 0~440V | ±(3%+3V) | 1V | |
(UI-N,UL-L,UL-E) | ||||
Frequency | DC,45~65Hz | ±1Hz | 1Hz | |
LoopResistance | 0~19.9V | ±(10%+0.2V) | 0.01V | |
(RL) | 10.0~99.9V | 0.1V | ||
RL CurrentTest | 0.5IΔΝ | ±(10%+10d) | 0.05IΔΝ | |
MultiplyingPower | x0.5,x1,x5 | |||
of test Current | ||||
Current Level(IΔΝ) | 10mA,30mA,100mA | |||
300mA,500mA | ||||
Trigger PhaseAngle | 0°or 180° | |||
RCD Test Current Selection Table | ||||
IΔΝ(mA) | IΔX1/2 (mA) | IΔX1(mA) | IΔX5(mA) | Auto(mA) |
10 | 5 | 10 | 50 | 10 |
30 | 15 | 30 | 150 | 30 |
100 | 50 | 100 | 500 | 100 |
300 | 150 | 300 | 1500 | 300 |
500 | 250 | 500 | ------- | 500 |