Quantity(Piece/Pieces) | 1 ~ 1000 | >1000 |
Est. Time(days) | 7 | To be negotiated |
If you finish the payment today, your order will ship out within the delivery date.
Performance
Spark proof during lead connection, reverse polarity protected Perfect for charging all 12V 24V lead-acid, batteries, AGM , GEL , Solar , dry, water batteries, lead-acid maintenance-free batteries, and safety charger. Complete 5-step charging program (Initialization, Bulk Charge, Float Mode) allows for optimization of battery power, without overcharging Automatic charge cycle functionality switches to float mode after fully charging the battery Solid state two color LED indicates stage of charger and if the battery voltage drops too far under load, full charger output power resumes
Parameter
Brand: LUNDA Item Weight:0.8kg Product Dimensions:175*135*75mm Cover Included:Battery charger and maintainer, Alligator clips, Output voltage: 6v/8v/12v/14v/16v/24v Amperage:12V-10A(max) 24V-8A(max) Power:200W Battery Type: lead-acid batteries, AGM , GEL , Solar , dry, water batteries, lead-acid maintenance-free batteries,( 58909564, including wett and dry).
Charging operation
INTELLIGENT Mode
Intelligent mode: The default intelligent charging mode at startup, the display shows "INTELLIGENT ", and the current gradually decreases when the charging is nearly completed. The intelligent mode is usually used for the conventional maintenance battery charging mode.
Charging operation
Prompt
There are two modes to choose, after the battery is connected, no personnel care is needed. 1. Under normal circumstances, it is recommended to use smart mode to charge and maintain the battery. 2. For low-temperature, long-term abandoned battery charging, it is recommended to use fast charging mode for repair charging. 3. This product adopts advanced microcomputer automatic management system in front, no matter whether you choose intelligent mode or fast charge mode, there is no need for personnel care.
Charging operation
Step 1, Examine and make sure rated voltage of battery is conforming to output voltage of charger. Step 2, Connect correctly the charger and the battery. Step 3, Examine and make sure mains supply voltage is conforming to input voltage of the charger. Step 4, Connect mains supply and the battery, watch to see if the indicator is on and the cooling fan is working when charging. Step 5, if the charger refuse to work, turn off mains supply immediately and check all the connecting cables between mains supply, the battery and the charger.
5-Stage Mode
No-load Mode when there has no load connected with charger,the LED Screen will show voltage only,the power is about 2W; Constant Current means the battery voltage is lower than the set voltage of charger,then the charger supply constant charging current to maintenance both battery and battery charger; Constant Voltage advanced pulse width modulation (PWM) technology,control the charger's current and output voltage accurate,avoid overcharge; Floating charge when the battery is going to be charged full,the charger will stop charging,but still supply constant floating voltage and small current to battery; Trickle charge when the battery voltage and current is approaching the set voltage and current,it will turn to trickle floating charge from automatic mode,it means charge full,also can be charged with floating mode.
After only a few minutes or even shorter time, the battery indicates fully charged. 1. Examine to see if there is overcurrent protection, overheat protection or low voltage protection resulted out of non-conforming voltage, and also examine if cooling fan is working. 2. Maybe the battery is consumed up or already fully charged (better test again after discharging or take other battery for testing purpose). 3. Add battery tune-up treatment or distilled water. 4. Examine and make sure output clips from charger is well connected to battery poles.
5-Stage Mode
No-load Mode when there has no load connected with charger,the LED Screen will show voltage only,the power is about 2W; Constant Current means the battery voltage is lower than the set voltage of charger,then the charger supply constant charging current to maintenance both battery and battery charger; Constant Voltage advanced pulse width modulation (PWM) technology,control the charger's current and output voltage accurate,avoid overcharge; Floating charge when the battery is going to be charged full,the charger will stop charging,but still supply constant floating voltage and small current to battery; Trickle charge when the battery voltage and current is approaching the set voltage and current,it will turn to trickle floating charge from automatic mode,it means charge full,also can be charged with floating mode.
After only a few minutes or even shorter time, the battery indicates fully charged. 1. Examine to see if there is overcurrent protection, overheat protection or low voltage protection resulted out of non-conforming voltage, and also examine if cooling fan is working. 2. Maybe the battery is consumed up or already fully charged (better test again after discharging or take other battery for testing purpose). 3. Add battery tune-up treatment or distilled water. 4. Examine and make sure output clips from charger is well connected to battery poles.