0 Piece,Product Price: US $ 0
Quantity(Piece/Pieces) | 1 ~ 1000 | >1000 |
Est. Time(days) | 7 | To be negotiated |
If you finish the payment today, your order will ship out within the delivery date.
Product Parameters |
||
Specification |
||
Model WD |
10212/24 |
|
Rated Power |
1000W |
|
Peak Power(20ms) |
3000W |
|
Start Motor |
1HP |
|
Battery Voltage |
12/24VDC |
|
Size(L*W*Hmm) |
340x165x283 |
|
Packing Size(L*W*Hmm) |
405x230x340(1pc) / 475x415x350(2pcs) |
|
N.W.(kg) |
10.5(1pc) |
|
G.W.(kg) |
12(1pc) |
|
Installation Method |
Tower |
|
Parameter |
||
Input |
DC Input Voltage Range |
10.5-15VDC(Single battery voltage) |
AC Input Voltage Range |
73VAC~138VAC / 145VAC~275VAC / 155VAC~285VAC / 165VAC~295VAC(700W~7000W) |
|
AC Input Frequency Range |
45Hz~65Hz |
|
Max AC charging current |
700W-7000W Model : 0A~20A (Depending on the model) |
|
AC charging method |
Three-stage (constant current, constant voltage, floating charge) |
|
Output |
Efficiency(Battery Mode) |
≥85% |
Output Voltage(Battery Mode) |
110VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%(Battery Mode) |
|
Output Frequency(Battery Mode) |
50Hz±0.5 or 60Hz±0.5 |
|
Output Wave(Battery Mode) |
Pure Sine Wave |
|
Efficiency(AC Mode) |
>99% |
|
Output Voltage(AC Mode) |
110VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10% |
|
Output Frequency(AC Mode) |
Tracking Automatically |
|
Output waveform distortion(Battery Mode) |
≤3%(Linear load) |
|
No load loss(Battery Mode) |
≤2.5% rated power (700W~7000W)/ ≤1% rated power(8KW~12KW) |
|
No load loss(AC Mode) |
≤2% rated power( charger does not work in AC mode) |
|
No load loss(Energy saving Mode) |
≤10W |
|
Battery Type |
VRLA Battery |
Charge Voltage :14V; Float Voltage:13.8V( 12V system; 24V system x2 ; 48V system x4; 96V system x8; 192V system x16) |
Customize battery |
Charging and discharging parameters of different types of batteries can be customized according to user requirements |
|
Protection |
Battery undervoltage alarm |
Factory default: 11V(Single battery voltage) |
Battery undervoltage protection |
Factory default: 10.5V(Single battery voltage) |
|
Battery overvoltage alarm |
Factory default: 15V(Single battery voltage) |
|
Battery overvoltage protection |
Factory default: 17V(Single battery voltage) |
|
Battery overvoltage recovery voltage |
Factory default: 14.5V(Single battery voltage) |
|
Overload power protection |
Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
|
Inverter output short circuit protection |
Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
|
Temperature protection |
>90°C(Shut down output) |
|
Alarm |
A |
Normal working condition, buzzer has no alarm sound |
B |
Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection |
|
C |
When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal |
|
Working Mode |
Battery First/AC First/Saving Energy Mode |
|
Transfer Time |
≤4ms |
|
Display |
LCD |
|
Thermal method |
Cooling fan in intelligent control |
|
Communication(Optional) |
RS232/RS485/APP(WIFI monitoring or GPRS monitoring) |
|
Environment |
Operating temperature |
-10℃~40℃ |
Storage temperature |
-15℃~60℃ |
|
Noise |
≤55dB |
|
Elevation |
2000m(More than derating) |
|
Humidity |
0%~95% ,No condensation |
|
Warranty |
1 year |
|