1.BF-D215B + LED display the current temperature difference, you can see high and low temperature zone temperature measurement point temperature; 2. high and low temperature and the temperature difference between the value of the temperature difference set value, and the temperature difference between the lower back to the difference between the control relay output; 3 . realization antifreeze circulating collector plate; 4. have temperature deviation correction function, can effectively adjust the temperature deviation due to the long distance transmission or caused by different measurement points; 5. power supply AC90V ~ 250V;
Functional overview
BF-D215B + microcomputer temperature control, mainly used in hot water circulation, backwater system control and other occasions o LED screen real-time display the current temperature difference, and can always view the high and low temperature zone
Temperature value of temperature measurement. Through the high and low temperature zone between the temperature difference and set the temperature difference, and the temperature difference between the lower part of the hysteresis to solve the relay output, to achieve cold and heat cycle, improve thermal efficiency,
But also to achieve the collector plate antifreeze cycle. At the same time with the temperature deviation correction function, can effectively correct due to long-distance transmission or due to different temperature points built temperature deviation o BF-D215B +
Ready to adjust the temperature deviation correction function, can effectively adjust the long distance from the transmission or due to different temperature points built temperature deviation o BF-D215B + with advanced power supply design, to ensure that the power supply
The controller is stable, reliable and continuous when changing between Ac90V and 250V.
Main works of arrows
- Two 10KNT ℃ temperature sensor input
All the way often open, often closed output
Temperature cycle function
Collector plate antifreeze function
High temperature view
Temperature difference display
Temperature deviation correction function
Power-down memory protection
Code Senation Job Description Setting range default value
1-H temperature difference 0-80 ℃ 10 ℃
1-P temperature difference lower limit hysteresis 1-30 ℃ 5 ℃
PH collector plate antifreeze temperature control value -1-8 ℃ 3 ℃
HS ℃ high temperature zone temperature deviation correction value -10-10 ℃ 0 ℃
LS ℃ low temperature zone deviation correction value -10-10 ℃ 0 ℃
Technical Parameters
Product packaging list 1 host 2 NTc (1OK) temperature sensing line two 3 manual
Dimensions (mm) Length 91x Width 40x Height 52
Installation and size "mm) Control clams available with standard DIN rail mounting or mounting, with distance between two mounting holes 84 mm
Weight Net Weight: 0 188Kg Gross Weight: 0 232Kg
Working power consumption Power Ac (90-250) V, 2W
Use j flat to fill -10 ℃ ~ 50 ℃
Display mode LED digital display
Press the push button
Input two 10K NTc thermistor temperature sensor input, measuring range. 50-120 ° C
Output
1-Lu Wei electrical normally open, normally closed contact temperature difference cycle output
2 auxiliary contact current capacity for the resistive load 5 amps, inductive load 1 amperes.
Can control 1000W of electric heating or 200V motor or water pump, larger load need to use AC contactor expansion
Capacity.
Measuring range Temperature measurement range: -50 ~ 120 ℃ temperature measurement range: -99 ~ 120 ℃
Set the range 0-80 ℃
Control range 0 ~ 80 ℃
Other parameters 1 temperature sensor clamor signal line length from the use of ordinary wire extension, the effective range of 100 meters 2 set parameters
The number of power to maintain long-term memory 3 temperature control hysteresis in the O ℃ ~ 30 ℃